| Electromagnetic compatibility | EN 55022 Class B; EN 301 489-1; EN 301 489-17; ICES-003 Class B; FCC Part 15, Class B |
| Medical compliance | EN60601-1-2 |
| Safety | UL 60950-1; IEC 60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; EN62479 |
| Radio | 802.11a/n, a/b/g/n |
| RF exposure | FCC Bulletin OET-65C; RSS-102; EN 300-328; ETS 301 893; CFR 47, Part 2, Subpart J; ANSI/IEEE C95.1 (99); Ministry of Health Safety Code 6; Australian Radiation Protection Std.; To ensure compliance with various national and international Electromagnetic Field (EMF) standards, this device should only be operated with HP-approved antennas and accessories. |
| Mobility | IEEE 802.11a High Speed Physical Layer in the 5 GHz Band; IEEE 802.11b Higher-Speed Physical Layer Extension in the 2.4 GHz Band; IEEE 802.11d Global Harmonization; IEEE 802.11g Further Higher Data Rate Extension in the 2.4 GHz Band; IEEE 802.11i Medium Access Control (MAC) Security Enhancements; IEEE 802.11n WLAN Enhancements for Higher Throughput |
| Ports | 1 RJ-45 autosensing 10/100/1000 port |
| Antenna | External antennas only; six Type N connectors; 6 external antennas |
| Operating humidity range | 5 to 95% (noncondensing) |
| Storage humidity | 5 to 95% (noncondensing) |
| Storage temperature range | -40 to 70°C |
| Operating temperature range | -40 to 55°C |
| Image legal disclaimer | Product image may differ from actual product |
| Minimum dimensions (W x D x H) | 12.5 x 21.01 x 24.99 cm |
| Weight | 2.75 kg |
| What's in the box | (1) HP MSM466-R Dual Radio Outdoor 802.11n Access Point (WW) |
| Technical notes | The MSM466 and MSM466-R access point power information listed does not include an antenna. Review the HP documentation for your AP to understand the maximum output setting for your AP based on your country's regulations.Three spatial stream AP, supporting 450 Mb/s per radio.Maximum transmit power varies by country.When used with an HP MIMO indoor antenna, the AP requires an RP-SMA to N Type adapter/cable (available separately).Outdoor antennas should be installed by a professional installer with proper grounding and lightning protection.Wind speeds are supported up to 165 m/h (265 km/h).Dimensions do not include the additional space required for cables.Regulatory model number: MRLBB-1102Additional Railway EMC emission standards: - EN 55011 - EN 50121-3-2 |
| Warranty | One-year next-business-day advance replacement (available in most countries), with extensions available;Electronic and telephone support: limited electronic and telephone support is available from HP refer to www.hp.com/networking/support for details on the support provided and the period during which support is available;Software releases: refer to www.hp.com/networking/support for details on the software releases provided and the period during which software releases are available for your product(s) |
| Frequency band and operating channels | Americas: 2.412 GHz-2.462 GHz (1 - 11 channels); 5.180 GHz-5.320 GHz (36 - 64 channels); 5.500 GHz-5.700 GHz (100 - 140 (excluding 5600-5650 MHz) channels); 5.745 GHz-5.825 GHz (149 - 165 channels); . European Union: 2.412 GHz-2.472 GHz (1 - 13 channels); 5.180 GHz-5.320 GHz (36 - 64 channels); 5.500 GHz-5.700 GHz (100 - 140 (excluding 5600-5650 MHz) channels); . Rest of World (Actual channels designated by selecting country in UI): 2.412 GHz-2.472 GHz (1 - 13 channels); 5.180 GHz-5.320 GHz (36 - 64 channels); 5.500 GHz-5.700 GHz (100 - 140 channels); 5.745 GHz-5.825 GHz (149 - 165 channels); . Taiwan: 2.412 GHz-2.462 GHz (1 - 11 channels); 5.280 GHz-5.320 GHz (56 - 64 channels); 5.500 GHz-5.700 GHz (100 - 140 (excluding 5600-5650 MHz) channels); 5.745 GHz-5.825 GHz (149 - 165 channels); . Japan: 2.412 GHz-2.472 GHz (1 - 13 channels); 5.180 GHz-5.320 GHz (36 - 64 channels); 5.500 GHz-5.700 GHz (100 - 140 channels); . Israel: 2.412 GHz-2.472 GHz (1 - 13 channels); |
| Power | IEEE 802.3af PoE compliant for Gigabit Ethernet for operation down to -4°F (-20°C). For operation down to -40°F (-40°C), IEEE 802.3at power is required.; Antenna is purchased separately.
For temperatures below -4°F (-20°C), IEEE 802.3at PoE power is required to run the embedded heater. The maximum power draw is 25 W. |
| Power consumption | 12.9 W (maximum) |
| Mounting | Outdoor IP67 and NEMA 4X;Includes hardware for pole and wall mount applications |